Product List
Gw9-24 Three-Pole Isolation Gate Knife
[May 10, 2024]Product model Rated parameters GW9-12 GW9-24 GW9-40.5 1 Rated voltage (kV) 12 24 40.5 2 Rated current (A) 630,1250 3 Disconnector Rated ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
Neutral Point Isolation Switch Single Grounding Gw13-72.5/1250A
[May 09, 2024]Name Unit GW13 product type Neutral Point Protection Device Isolation Switch (35-110) Kv Rated voltage kV 40.5 72.5 126 Rated current A 630,1250 Rated frequency Hz 50/60 Rated ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
Neutral Point Isolation Switch Single Grounding Gw13-40.5/1250A
[May 09, 2024]Name Unit GW13 product type Neutral Point Protection Device Isolation Switch (35-110) Kv Rated voltage kV 40.5 72.5 126 Rated current A 630,1250 Rated frequency Hz 50/60 Rated ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
Neutral Point Isolation Switch Single Grounding Gw13-72.5
[May 09, 2024]Name Unit GW13 product type Neutral Point Protection Device Isolation Switch (35-110) Kv Rated voltage kV 40.5 72.5 126 Rated current A 630,1250 Rated frequency Hz 50/60 Rated ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
Neutral Point Disconnector Switch Gw13-40.5/1250A
[May 09, 2024]Name Unit GW13 product type Neutral Point Protection Device Isolation Switch (35-110) Kv Rated voltage kV 40.5 72.5 126 Rated current A 630,1250 Rated frequency Hz 50/60 Rated ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
Neutral Point Disconnector Switch Gw13
[May 09, 2024]Name Unit GW13 product type Neutral Point Protection Device Isolation Switch (35-110) Kv Rated voltage kV 40.5 72.5 126 Rated current A 630,1250 Rated frequency Hz 50/60 Rated ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
40.5-550kv, Three-Column Rotary High-Voltage Disconnectors
[May 09, 2024]We customize our products according to customer requirements. 1 Overview GW7F series disconnector is the three colums,double break,horizontally reverse type ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
Gw22A-126/145/252/363/550 Series Outdoor Three-Phase High-Voltage AC Disconnector with Single ...
[Apr 29, 2024]name (of a thing) unit (of measure) GW22A Product Type single column vertical fracture single arm telescopic clamp type rated voltage kV 72.5 126 170 252 363 420 550 rated ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
72.5/126/145/170/252/363/420/550kv Outdoor Three-Phase High Voltage AC Disconnector Switch
[Apr 29, 2024]Name (of a thing) Unit (of measure) GW23A Product Type double-column horizontal fracture semi-pantograph clamp type rated voltage kV 72.5 126 170 252 363 420 550 rated ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
Gw7f Series Disconnector
[Apr 25, 2024]Name (of a thing) unit GW7 Product Type Three columns flip horizontally rated voltage kV 40.5 72.5 126 145 170 252 363/420 rated current A 2000,2500,3150,4000,5000 Rated ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
126/145/170 /252/363/420/550kv Disconnector
[Apr 25, 2024]Name (of a thing) unit GW7 Product Type Three columns flip horizontally rated voltage kV 40.5 72.5 126 145 170 252 363/420 rated current A 2000,2500,3150,4000,5000 Rated ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
Double Column Vertically Open The Single Break-40.5kv
[Apr 25, 2024]Serial No. Project Unit Technical Parameters 12kV 24kV 40.5kV 1 Insulation distance across the isolating distance mm ≥200 ≥300 ≥400 2 Insulation distance to ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
Double Column Vertically Open The Single Break-24kv
[Apr 25, 2024]Serial No. Project Unit Technical Parameters 12kV 24kV 40.5kV 1 Insulation distance across the isolating distance mm ≥200 ≥300 ≥400 2 Insulation distance to ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
Double Column Vertically Open The Single Break Disconnecting Switch-24kv
[Apr 25, 2024]Serial No. Project Unit Technical Parameters 12kV 24kV 40.5kV 1 Insulation distance across the isolating distance mm ≥200 ≥300 ≥400 2 Insulation distance to ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.
Double Column Vertically Open The Single Break -12kv
[Apr 25, 2024]Serial No. Project Unit Technical Parameters 12kV 24kV 40.5kV 1 Insulation distance across the isolating distance mm ≥200 ≥300 ≥400 2 Insulation distance to ...
Company: Shandong Taikai Intelligent Power Distribution Co., Ltd.